Amnesic Compression for Self-Observation
A method taken from the instrument of CRITERIA 03 · LETHE · LELANTOS: the state vector, principal component analysis that forgets, and its verification. An R&D memo.
Problem
Screens of generative and sensor systems list many quantities. A list of quantities, however, does not show the state of the system as a whole. Showing the state requires reducing dimensions, and if the system is non-stationary, the reduction itself must be updated over time. This memo records a minimal method by which a system compresses and shows its own state inside a browser’s render loop, without external models or weights.
The State Vector
In step with the existing scan cycle, eleven quantities are taken roughly every 0.1 s: (1) mean velocity of the bodies, (2) maximum velocity, (3) mean luminance, (4) share of bodies in the ring, (5) mean radius, (6) impacts in the window, (7) absorptions in the window, (8) entropy increment in the window, (9) number of flashes, (10) number of glitches, (11) drag speed. Velocity, radius and drag are divided by the screen’s base length so they do not depend on device resolution. Raw values are MEAS.
Impacts, absorptions and increments are sparse in a 0.1 s window, so an exponential smoothing with a time constant of about 1 s is applied (DERIV).
Cumulative entropy S is excluded. A monotonic quantity would make the trajectory flow in one direction by construction — an outcome of design, not of observation (paper, section 3). Note that under amnesic standardisation, including S would not even preserve its monotonicity; it would be cancelled by normalisation. A non-returning trajectory would require treating S alone with non-forgetting normalisation, which would be deliberate construction outright.
Amnesic Standardisation and CCIPCA
Each quantity tracks its mean and variance incrementally and is standardised to a z-value (DERIV). The update weight is 1/n, with n capped at 600 (about 60 s); without the cap the weight tends to zero and the instrument stops forgetting. z-values are clipped at ±5, because a low-variance quantity spiking on a rare event would otherwise capture an axis by itself.
Three principal components are found incrementally by CCIPCA (Weng et al., 2003). No covariance matrix is kept: each sample updates the component vectors, and the residual after removing a component is passed to the next. The amnesic parameter l is 2, set to 0 for the first 20 samples only (to avoid negative coefficients early on). The length of each component vector is the estimate of its eigenvalue.
The first 50 samples (about 5 s) have not converged, so no coordinates are shown; the readout says “MODEL --” (withheld).
The z-vectors of the last 600 samples are kept and projected onto the current axes every frame. PC1 and PC2 are drawn at the same scale (three standard deviations of PC1 fitted to the frame); PC3 is mapped to brightness. The share of variance is each eigenvalue divided by the amnesic mean of the squared norm of z. Δθ is the angle between the direction of PC1 recorded each second and its direction ten seconds earlier (sign flips ignored). All of these are MODEL.
The computation — 11 dimensions × 3 components × about 10 Hz — is negligible; any load comes from drawing alone. While the latent space is shown, particle rendering stops, so it is lighter than the physical view.
Verification
Agreement with batch PCA. 3,000 samples of synthetic data with a known three-factor structure were streamed and compared against batch PCA over the latest 600 samples. PC1 differed by 0.87°, PC2 by 1.18°; the first eigenvalue was 5.31 against 5.40.
Speed of forgetting. When the factor structure was switched mid-stream, PC1 approached the new structure within about 30 s and had moved about 48° away from the old one by about 60 s. The readout “memory ~60s” is consistent with this. The “~” is a rounding, however: effective memory spans 30 to 60 s.
Errors found. (1) The denominator of the share of variance was fixed at the dimension count, 11, so the readout showed 247% at start-up, since the variance of z greatly exceeds 1 early on. The denominator was changed to the amnesic mean of the measured squared norm. (2) On mobile, the latent-space frame overlapped the glyph column at the right, and outlying trajectory spilled beyond it. The frame was fitted between the screen elements, and the trajectory is clipped to the frame. Both were found by inspecting renders in a headless browser.
An error found after publication. The denominator of the share of variance (the amnesic mean of the squared norm) was updated with weight 1/n, while CCIPCA estimates the components with weight (1+l)/n; the two did not match. Because the denominator remembered further back, the share was overstated right after an abrupt change of state: with synthetic data whose amplitude jumped sixfold mid-stream, it read up to 94% where the settled value was about 63%. It surfaced as 124% while reproducing the rejected design for the note. The denominator now uses the same (1+l)/n weight, and under the same conditions the share stays at about 63% (17 September 2026).
A run. After 80 s, the shares settled at PC1 38%, PC2 10%, PC3 10%, with Δθ at 2.3°/10 s. These are the values of one run and vary from run to run with the random numbers.
Trade-offs, and Directions for Verification
Both sides, honestly.
Advantages. No external model, weights or network; it completes within a single HTML file. It fits the existing MEAS / DERIV / MODEL grammar as it is. The axes follow a non-stationary system. The computation is light. The forgetting window can be disclosed directly as a “length of memory.”
Disadvantages. Being linear, non-linear structure is flattened. The choice of state vector largely decides the image — this is where the designer’s judgement enters most heavily. The forgetting window is a chosen value, so Δθ reflects both the system and the design. Agreement with batch PCA was checked on synthetic data; convergence on LETHE’s actual data was confirmed only by inspection and the stability of the numbers. Frame rates differ between a headless browser and real devices, so the actual sampling period (about 0.1 s plus one frame) fluctuates.
Directions. (1) Compare with non-linear compression to measure what linearity loses — at the cost of importing external weights and giving up the single-file advantage. (2) Take the distribution of Δθ across forgetting windows, to separate the system’s contribution from the design’s. (3) Apply the same method to the footage of CRITERIA 01 and 02; image embeddings would then need local computation. (4) Decide how the disclosure grammar should distinguish the two meanings of MODEL — assumed from time, and fitted to data.
draft v0.1 — no figures. For the ideas and decisions, see the process paper (Seeing What Moves Unseen).
SEISMOSCOPE — observation instruments / SISTER RAY (Motoki Takeuchi). draft v0.1.